Lantronix UDS2100

SPHINX in Europe
IE
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • PL
  • ES
  • SE
  • CH
  • UK
Product groups > Embedded Device Networking > Lantronix UDS2100

Lantronix UDS2100

External device servers

Lantronix UDS2100
8411_37211.png
8411_37212.jpg
  • PropertiesProperties
  • DescriptionDescription
  • Further InformationFurther Information
  • PDFPDF
  • Network virtually any device in minutes
  • Access, monitor and control equipment over Ethernet
  • Replace dedicated PCs and/or modem lines with fast and reliable Ethernet networking
  • Configure quickly and easily via HTTP, DHCP, Telnet, serial or Lantronix DeviceInstaller™ utility
  • Two DB9M DTE serial ports supporting RS232, RS422 and RS485
  • Environmentally-friendly RoHS and WEEE compliant
  • Features TruPort® Com port control technology

The UDS family of device servers enables users to connect, manage and control just about any piece of equipment with a serial port from virtually anywhere over Ethernet or the Internet.

With the UDS2100, two pieces of equipment of virtually any type can be added to an Ethernet network in a matter of minutes! This dual-port device server is a quick, simple and inexpensive way to bring the advantages of remote management and control to equipment not currently connected to a network.



Extending Serial Communications Across the Globe

Our approach to network-enabling devices is transparent to your attached equipment and software so you won?t need to change the way you work. Using a method called serial tunneling, the UDS2100 encapsulates serial data into packets and transports it over Ethernet. Serial tunneling can be done in two ways:



  • Using Lantronix supplied Com Port Redirector software, Windows® device applications not designed for network communications are re-directed to communicate to devices connected to the UDS2100.
  • Connecting two UDS2100 device servers configured to automatically talk to each other over the network creates virtual serial connections that can extend serial communications across a facility or around the world.

The built-in web server enables users to access and configure the UDS2100 from a standard web browser. Using Lantronix development tools, users can build web pages to customize the UDS2100 for unique applications.

On-board Flash memory provides room for future system software upgrades and maintenance-free, nonvolatile web page storage.

Easy to Set Up and Use

The UDS2100 can be set up locally through its serial port, or remotely using Telnet or a web browser. The included DeviceInstaller Windows-based configuration software simplifies setup and provides an easy way to:

  • Assign IP & other network specific addresses

  • Load custom web pages
  • Enable web-based configuration of the device server
  • Ping or query the attached device(s) over the network
  • View specific device data files
  • Upgrade firmware


Modem Replacement

In modem emulation mode, the UDS is used to replace dial-up modems. The unit accepts modem AT commands on the serial port. It then establishes a network connection to the end device, leveraging network connections and bandwidth to eliminate dedicated modems and phone lines.



Total Com Port Control with TruPort Technology

Built into the included Com Port Redirector software, TruPort® technology enables Windows-based applications to access and control serial ports on the UDS2100 as if they were actually local PC serial ports. The application can monitor and set hardware pins on the UDS2100 serial ports as well as access serial buffers for total Com port control. This allows existing applications to seamlessly transition from controlling local devices to true remote monitoring and control of devices around the world.




ProdGrafik

Serial Interface

    Interface: Software-selectable RS232, RS422 or RS485 (2 and 4 wire support)
    Connectors: 2 DB9M DTE serial ports
    Data Rates: Software-selectable baud rate from 300 to 921 KBaud
    Characters: 7 or 8 data bits
    Parity: odd, even, none
    Stop Bits: 1 or 2 Control
    Signals: CTS/RTS (Hardware)
    Flow Control: XON/XOFF (Software)


Network Interface

    Interface: 10Base-T/100Base-TX Ethernet port
    Software selectable Ethernet speed 10/100/Auto
    Software selectable Half/Full/Auto duplex Connectors: RJ45
    Standards: ARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, Telnet, TFTP, and RFC2217


Indicators (LED)

    Power (blue)
    RXI Serial (Activity) (green)
    TXI Serial (Activity) (yellow)
    RX2 Serial (Activity) (green)
    TX2 Serial (Activity) (yellow)
    RJ45 LEDs Link (100=green,10=yellow)
    Act (Full=green, Half duplex=green)


Processor

    CPU: Lantronix DSTNI-EX 48 MHz clock
    Memory: 256 KB zero wait state SRAM, 2 MB Flash


Management

    Lantronix DeviceInstaller GUI, Serial login, SNMP, Telnet login, HTTP


Power

    9-30 VDC on barrel connector (1.8 Watts maximum consumption)


Environmental

    Operating: 0° to 60° C (32° to 140°F)
    Storage: -40° to 85° C (-40 to 185°F)


Packaging

    Material: Metal enclosure with integrated wall mounts; optional 35 mm DIN-rail mount available
    Dimensions (LxWxH): 9.5 x 7.2 x 2.3 cm (3.7 x 2.8 x 0.9 in)
    Weight: 0.4 kg (0.9 lbs)
    IP Rating: 30


Agency Approvals
    FCC, C/UL, CSA, VCCI, CE,TUV, CTick


Shipping Dimensions

    Dimensions (LxWxH): 35.5 x 17.1 x 7.6 cm (14 x 6.75 x 3 in)
    Weight: 1.5 kg (3.0 lbs)


Included Software

    Windows® 98/ME/NT/2000/XP-based DeviceInstaller configuration software, Com Port Redirector software and related utilities


Emissions


FCC Part 15 Subpart B Class A Radiated Emissions 30MHz - 1000MHz
ICES-003 Issue 4 February 2004 Class A Radiated Emissions 30MHz - 1000MHz
AS/NZS CISPR 22: 2004 Class A Radiated Emissions 30MHz - 1000MHz
EN55022: 1998 + A1: 2000 + A2: 2003 Class A Radiated Emissions 30MHz - 1000MHz
VCCI V-3/2005.04 Class A Radiated Emissions 30MHz - 1000MHz
EN61000-3-2: 2000 Class A Harmonic Current Emissions
EN61000-3-3: 1995 + A1: 2001 Fluctuations and Flicker


Immunity


EN55024: 1998 +A1: 2001 +A2: 2003
IEC_61000-4-2: 1995 ESD 8kV Air Discharge (Direct), 4kV Contact Discharge (Direct/Indirect)
IEC_61000-4-3: 1995 Radiated Immunity 3.0V/m, 1KHz AM Sine Wave at 80%
IEC_61000-4-4: 1995 EFT/Burst 1.0kV Power Lines, 0.5kV I/O Lines
IEC_61000-4-5: 1995 Surge Immunity 1.0kV Common Mode, 1.0 kV Differential Mode
IEC_61000-4-6: 1996 Conducted Immunity 3.0 Vrms, 80% AM Modulated (1KHz)
IEC_61000-4-8: 1993 Magnetic Field Immunity 50Hz 1.0 Arms/m
IEC_61000-4-11: 1994 Voltage Dips and Interrupts (>95%,0.5 periods), (30%,25 periods), (>95%,250 periods)


Isolation

  • Designed with protection against transients and ESD for use under harsh environments.
  • Serial Port: 15 kV ESD protection on RS232 and RS422/485 transceivers
  • Power Input: Up to non-repeated 600 W 10/100 usec pulse protection against transient over voltages
  • Ethernet Port: 1500 VAC isolation shielded with shield connected to chassis ground for signal integrity and ESD protection



Ordering Information


Part Number Description
UD2100001-01 UDS2100 two-port device server
- US domestic 110 VAC power supply
- DB9F-to-DB9F Null Modem cable (P/N 500-164-R)
- CD Includes: User Guide and Software utilities
(DeviceInstaller™ and Com Port Redirector™)
- Quick Start Guide
UD2100002-01 UDS2100 two-port device server
- 100-240 VAC International power supply with regional adapters
- DB9F-to-DB9F Null Modem cable (P/N 500-164-R)
- CD Includes: User Guide and Software utilities
(DeviceInstaller™ and Com Port Redirector™)
- Quick Start Guide
500-163-R DB9F-to-DB25M serial cable
500-164-R DB9F-to-DB9F Null modem cable
500-171-R DB25M-to-RS485 and power input terminal adapter
ACDIN2001-01 DIN-rail mount UDS2100



Customers who viewed this item also viewed
Accept all Reject Configure

This website uses cookies to provide the best possible experience. More information.